Fire prevention by nitrogen for ICT & Data Centers
Optimal fire prevention of server rooms with oxygen reduction system
In ICT environments and data centers, continuity is crucial. A minor electrical failure, overheating or cable problem can lead to fire with major consequences: damage to hardware, data loss and prolonged downtime. Traditional sprinkler systems are often unsuitable because of the risk of water damage.
Presscon and FX prevent provide nitrogen-based fire prevention by reducing oxygen levels in a controlled manner to a level where fire cannot develop. With no water, no damage, no residue and no impact on sensitive IT infrastructure. Contact our specialists for an oxygen reduction system or request a quote directly.
Why choose oxygen reduction?
Prevention is better than cure: after all, no oxygen means no fire. The technique of expelling oxygen with nitrogen is our core business. Oxygen reduction is suitable for closed spaces where vulnerable products are stored, such as ICT and data centers. Presscon and FX prevent can also perform an analysis at your company to investigate whether nitrogen is a suitable solution.
Need advice for your business or industry?
How fire prevention using nitrogen with oxygen reduction system works
An Oxygen Reduction System(ORS) is a proactive fire prevention solution that prevents fire from starting. It does this by reducing the oxygen level in a protected area in a controlled manner below the limit at which a fire cannot propagate. The reduction is achieved by the controlled addition of nitrogen to the environment.
Unlike traditional fire protection systems,such as sprinklers or gas extinguishing systems, which are activated only after fire or smoke is detected, an oxygen reduction system operates preventively continuously. The system prevents a fire from developing at all by keeping the oxygen level permanently below the ignition threshold.
Presscon and FX prevent realizes this solution with on-site nitrogen generation, which can be used to create a reliable environment in server rooms, technical rooms and other critical areas, among others. Depending on the product stored and the application, the desired oxygen percentage is determined. It then examines how the system can be used in the most energy-efficient way. One installation can monitor multiple rooms simultaneously, each with its own oxygen level.
Presscon and FX prevent’s oxygen reduction system uses advanced technology to accurately monitor and control this low oxygen concentration. The system is equipped with high-quality oxygen sensors that continuously monitor the oxygen content in the protected area. Based on these measurements, the nitrogen supply is automatically adjusted to maintain the desired and safe low-oxygen (LOX) environment. This creates a stable environment in which fire risks are structurally eliminated, without the use of traditional extinguishing agents. Presscon and FX prevent do not extinguish a fire, but prevent fire from starting and propagating.
What are the benefits of an oxygen reduction system for data centers?
The oxygen reduction system is designed to maintain optimal conditions for sensitive electronic equipment, making it an ideal solution for data centers and IT facilities.
- Continuous fire prevention: Reduces the risk of fire before it occurs.
- Non-invasive: Does not damage equipment or require cleaning, unlike water or foam systems.
- Operational security: Ensures uninterrupted operation of data centers during operation.
- Cost efficiency: Reduces the need for costly fire damage repairs and downtime.
If your business contains sensitive equipment, critical data or valuable assets that should not be exposed to water, foam or chemical extinguishers, an oxygen reduction system is an excellent choice. Contact our experts for a customized consultation.
Monitoring, signaling and operation of the oxygen reduction system
At the entrance, the oxygen level is clearly visible on a digital display. In case of an unwanted situation, a clear alarm with flashing light and alarm horn sounds. The oxygen reduction system operates continuously and has a user-friendly touchscreen display that makes operating the system very easy. Visual display of alarms makes troubleshooting and troubleshooting easier.
Our certificates
NEN-EN-16750
We design, install and maintain our system in accordance with the requirements of NEN-EN-16750, the generally accepted European standard for oxygen reduction systems.
50104:2019/A1:2023
Our LOX Detect precision sensors are approved by VdS Schadenverhütung GmbH for use in fire prevention systems. VdS is Europe’s leading independent certification body specializing in fire safety. And also according to the european standard: EN 50104:2019/A1:2023.
ISO 8573-1:2010
The compressed air system meets the standards for ISO 8573-1:2010: it specifies purity classes of compressed air.
VCA-certified
All technicians are VCA certified.
Sustainability Goals
Sustainability is an integral part of every nitrogen system we design for ICT or data center. By developing and manufacturing all systems in our own Dutch factory, we limit transportation, reduce material waste and maintain full control over quality over the long term.
Our HP-PSA technology significantly reduces compressed air consumption, resulting in reduced energy consumption while maintaining stable, pure nitrogen. Thanks to its modular design, only individual components need to be replaced during maintenance, minimizing waste and downtime.
For ICT and data centers, this means a future-proof solution: stable processes, reduced environmental impact and nitrogen systems designed for long-term efficiency.
Presscon and FX prevent: your partner in fire prevention
At Presscon and FX prevent, we understand that your business is unique. That’s why we provide custom installations that are completely tailored to your needs and the layout of your business. Nitrogen purity can be set from 95% to 99.9999%, depending on the application.
Whether you run a small data center or manage a large server room, we provide the right nitrogen solution. With more than 30 years of experience, we are specialists in nitrogen generation and inerting. All systems are designed and manufactured in-house, allowing full quality control and customization.
Want to know how a nitrogen generator from Presscon and FX prevent will address your fire prevention needs? Contact one of our specialists.
Why choose Presscon?
- Custom-built systems: designed to your specifications and fully assembled in our own factory.
- Energy-efficient operation: HP-PSA technology delivers significant cost savings and sustainability benefits.
- 24/7 service: Dedicated support and fast on-site response to minimize downtime.
Questions about nitrogen solutions for ICT and data centers
Presscon specializes in the design, construction and maintenance of nitrogen generation systems, fire prevention systems and innovative solutions using compressed air and nitrogen.
Frequently Asked Questions
What is the difference between fire detection and fire prevention?
Fire detection signals smoke or heat when a fire has already started. Fire prevention, such as oxygen reduction, prevents fire from starting and propagating in the first place.
Is an oxygen reduction system safe for equipment and facilities?
Yes. Nitrogen is inert, dry and leaves no residue. The system does not adversely affect electronic equipment or data carriers.
How is the oxygen level in the server room monitored?
With advanced oxygen sensors that measure oxygen levels 24/7. The system automatically adjusts to keep the set level stable.
Can an oxygen reduction system be combined with other fire protection?
Yes. Oxygen reduction system can be combined with fire detection, alarms and compartmentalization for a layered safety strategy.